| Access Key |
Function |
Default Value |
Allowed Values |
| 0 |
Master Code |
1234 |
0000-9999 |
| 1 |
User Code 1 |
1111 |
0000-9999 except Master Code |
| 2 |
User Code 2 |
2222 |
0000-9999 except Master Code & User
Code 1 |
| 3 |
User Code 3 |
3333 |
0000-9999 except Master Code & User
Code 1,2 |
| 4 |
Key Relay Time (0.01 - 99.99 sec) |
0500 |
0000 Latch Mode
0500 5.00 Sec
9999 99.99 Sec |
| 5 |
Aux Relay Time (0.01 - 99.99 sec) |
0050 |
0000 Latch Mode
0500 5.00 Sec
9999 99.99 Sec |
| 6 |
System Mode |
0110 (X=0 or 1) |
0110 (Internal LED Mode, User Codes 1, 2
enabled, User Codes 3 disabled).
0xxx Internal LED Mode
1xxx External LED Mode
x0xx Disable User Code 1
xx0x Disable User Code 2
xxx0 Disable User code 3
x1xx Enable User Code 1
xx1x Enable User Code 2
xxx1 Enable User Code 3 |
| 7 |
LED Trigger Polarity |
0000 |
0000 Negative level trigger
0001 Positive Lever Trigger |
| 8 |
Panic Key Enable |
0000 |
0000 Disable
0001 Enable |
| 9 |
Security Level |
0001 |
0000 No safety level set
0001 After 4 successive wrong codes, stay
idle 30 sec.
0002 After 4 successive wrong codes, stay
idle 60 sec.
0003 After 4 successive wrong codes, stay
idle until Master Code is entered.
0004 After 4 successive wrong codes, Aux relay
closes. |