The Zeta Fire Premier L Conventional Panel

- From Only: £1,325.23 + VAT
- Brand: ZETA

The Premier L range of control panels are built to EN54 Pt 2 & 4. Its
LCD display can have zone labels entered for each zone to assist in
alarm location. It can be set up via the panel, or using a PC and a
VT100 terminal Program.
The panel is available in sizes varying from 20 to 48 zones in 4 zone
increments.
• Microprocessor based conventional... Read more »

Scroll down for options, pricing & availability!
Ask a Question View Specs BUY NOW
Ref | Product Name | Stock | Price | QuantityTap in Req. Qty |
16 Zone Panel
|
![]() |
£1,472.49 + VAT
(£1,766.99 inc VAT) |
||
20 Zone Panel
|
![]() |
£1,619.76 + VAT
(£1,943.71 inc VAT) |
||
24 Zone Panel
|
![]() |
£1,766.99 + VAT
(£2,120.39 inc VAT) |
||
28 Zone Panel
|
![]() |
£1,914.25 + VAT
(£2,297.10 inc VAT) |
||
32 Zone Panel
|
![]() |
£2,061.50 + VAT
(£2,473.80 inc VAT) |
||
36 Zone Panel
|
![]() |
£2,208.72 + VAT
(£2,650.46 inc VAT) |
||
40 Zone Panel
|
![]() |
£2,355.98 + VAT
(£2,827.18 inc VAT) |
||
44 Zone Panel
|
![]() |
£2,503.24 + VAT
(£3,003.89 inc VAT) |
||
48 Zone Panel
|
![]() |
£2,650.48 + VAT
(£3,180.58 inc VAT) |
||
Premier L Serial Repeater Panel
|
![]() |
£1,325.23 + VAT
(£1,590.28 inc VAT) |
||
The Premier L range of control panels are built to EN54 Pt 2 & 4. Its
LCD display can have zone labels entered for each zone to assist in
alarm location. It can be set up via the panel, or using a PC and a
VT100 terminal Program.
The panel is available in sizes varying from 20 to 48 zones in 4 zone
increments.
• Microprocessor based conventional fire alarm control panel
complies with EN54-2 & 4
• 20, 24, 28, 32, 36, 40, 44 or 48 detection zones
• 15 characters of programmable text per zone
• Programmable via the front panel or a serial terminal
• 16 event fire log
• 16 event fault log
• One man test facility
• Two sets of volt free changeover contacts operable on fire
• One set of volt free changeover contacts operable on fault
• Head removal via zener clamp or active end of line unit
• Non-latching zone facility
• Global class change input
• Individual class change inputs for each alarm zone
• Zone, alarm zone, and auxiliary contacts disablement
• 28V 250mA fused auxiliary output
• Repeater drive built in
• Remote silence & fault inputs
• Switched 28V supply
activated in fire for
contactor drive
• 16 x 2 backlit LCD
• IP 43
Additional Info